Free shipping from €49.90

DISPOSABLE GLOVE SENSINITRYL PRO IN NITRILE SMALL 100 PIECES BERICAH

€7,89
Tax included, shipping and discounts calculated at checkout.
BERICAH  |  SKU: 985625464  |  Barcode: 8024151814493


Shipping Costs and Times

  • Order fulfillment within 24 hours and delivery within the following 48/72 hours.
  • Shipping cost: always free for orders over €49.90, otherwise it costs €4.99.

Payments

Payment information is processed securely. We do not store credit card information or have access to your credit card information.

Returns and Refunds

You can return and receive a refund for the item within 30 days. See full policy here.

Assistenza Clienti BFarma +39 347 093 4913

Do you need help?

Our customer service is here to help you!

  • Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
  • For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .

We are always at your side to offer you fast and effective support!

Description

DISPOSABLE GLOVE SENSINITRYL PRO IN NITRILE SMALL 100 PIECES BERICAH


BERICAH


SENSINITRYL PRO

Description
Disposable non-sterile, powder-free nitrile gloves.
Latex-free and phthalate-free, protects against possible allergic reactions related to natural rubber latex proteins. Blue in color, ambidextrous with tear-proof cuff. Micro-rough surface that guarantees maximum sensitivity and a better grip. Excellent chemical resistance to disinfectants and main substances used in the chemical/pharmaceutical field.
The glove must be worn before starting the operational activity. The choice of glove must be based on the knowledge of the work activity and the work process of the operator, taking into account the working conditions and the associated risks.
Keep the packaging for further information and to ensure traceability. The product does not require the use of safety data sheets.
Indicated to protect the user and the patient from biological risks arising from microbial contamination and contamination by chemical agents in the clinical (examination, exploration, therapy, diagnostic) dental, pharmaceutical, chemical fields. Suitable for use in any type of patient allergic to latex. Not indicated for users/patients allergic to nitrile.

How to use
Disposable glove for use in chemically and mechanically non-aggressive activities; Keep the packaging for further information and to ensure traceability; avoid direct exposure to sunlight, ozone and heat sources; always carry out a preliminary test in real conditions of use; do not use the gloves in contact with the tested chemical product for periods exceeding those relating to the performance level (0<10 min; 1>10 min.; 2>30 min.; 3>60 min.; 4>120 min.; 5>240 min.; 6>480 min.); wear the gloves with dry and clean hands. The product does not require safety data sheets.

Warnings
Avoid direct exposure to sunlight, ozone and heat sources. Single-use only, non-reusable device to avoid cross-contamination. Avoid using gloves in situations where there is a risk of getting caught in moving parts of machines. The material may contain traces of chemical residues from processing which, although not detectable by laboratory tests, could be potentially dangerous for hypersensitive subjects (potential type IV chemical allergens). In case of confirmed hypersensitivity, request the Technical Data Sheet from the manufacturer. Contraindicated for patients and users who are sensitive or allergic to nitrile. Use on hands with long or unkempt nails and rings could cause the device to tear. This information does not reflect the actual duration of protection in the workplace and the differentiation between mixtures and pure chemical products. Chemical resistance has been evaluated under laboratory conditions from samples taken from the palm only (except where the glove is 400 mm or more in length, in which case the cuff is also tested) and is related only to the chemical tested. Resistance may differ if the chemical is used in a mixture. It is recommended that gloves are tested for suitability for the intended use as workplace conditions may differ from the type test depending on temperature, abrasion and degradation. During use, protective gloves may provide reduced resistance to hazardous chemicals due to changes in physical properties. Movement, rubbing, and deterioration caused by chemical contact, etc. can significantly reduce the effective wearing time. For corrosive chemicals, degradation may be the most important factor to consider when selecting chemical resistant gloves. In the event of serious accidents occurring while using the device, the user must promptly report the incident to the manufacturer and the competent authorities.

Conservation
Store gloves in their original packaging in a dry and clean place, avoid direct exposure to sunlight, heat sources and humidity.
Validity with intact packaging: 60 months.

Format
Pack of 100 pieces, size S.

Cod. GUN172S