Free shipping from €49.90

Glucomen Areo Sensor Blood Glucose Test Strips 50 Pieces Glucomen

€26,29 €70,00
Tax included, shipping and discounts calculated at checkout.
A.MENARINI DIAGNOSTICS  |  SKU: 939605046


Shipping Costs and Times

  • Order fulfillment within 24 hours and delivery within the following 48/72 hours.
  • Shipping cost: always free for orders over €49.90, otherwise it costs €4.99.

Payments

Payment information is processed securely. We do not store credit card information or have access to your credit card information.

Returns and Refunds

You can return and receive a refund for the item within 30 days. See full policy here.

Assistenza Clienti BFarma +39 347 093 4913

Do you need help?

Our customer service is here to help you!

  • Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
  • For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .

We are always at your side to offer you fast and effective support!

Description

GLUCOMEN AREO SENSOR BLOOD GLUCOSE MEASUREMENT STRIPS 50 PIECES GLUCOMEN


GLUCOMEN AREO


GlucoMen
air sensor

Description
In vitro diagnostic medical device.
Sensors for the quantitative determination of glucose levels in fresh capillary whole blood; to be used exclusively with the GlucoMen areo 2K instrument.
The sensors are designed for monitoring and self-monitoring of blood glucose levels in people with diabetes mellitus; they can also be used in hospital settings by healthcare professionals.
It is not intended for use in the diagnosis or screening of diabetes or for use in newborns.
Do not change your treatment based on test results without first consulting your doctor or health care professional.

General characteristics
Blood glucose measurement specificity for beta-D-glucose in blood
Enzyme composition (per cm2 ) of a test strip for measuring blood glucose - glucose oxidase (from Aspergillus niger ), 3.5%
- mediator: hexacyanoferrate (III) ion, 17.5%
- non-reactive substances, 79%
Unit of measurement
Glucose mg/dL (not modifiable)
Measuring range
Glucose 20-600 mg/dL
Response time
Glucose 5 seconds
Sample volume
Glucose 0.5 microL
Acceptable Hematocrit Range
Glucose automatically corrects the measurement based on the hematocrit (10-70%)
Correlation plasma equivalent
Sample fresh capillary whole blood
Sensor Coding self-coding
Hygiene Automatic ejection of the test strip via dedicated ejection button
Sampling automatic blood sample aspiration by capillary action
Use of alternative sites (AST) allowed (palm and forearm)
Operating environment Temperature range: 5-45°C
Humidity: 20%-90% (non-condensing)

How to use
1. Insert a new GlucoMen areo Sensor (white) into the sensor port. The drop symbol will start flashing on the display and the glucose symbol "Glu" will appear in the bottom left corner. If nothing appears on the display, remove the sensor, reinsert it into the port and wait for the drop symbol to start flashing.
For information on how to use the lancing device, read the instructions for use provided with it.
2. Hold the tip of the sensor in contact with the drop of blood until the control window fills. You will then hear a beep (if enabled) and the display will show a countdown.
3. Read the test results. A beep will announce the appearance of the test result on the screen with the glucose symbol "Glu".
4. To remove the sensor, press the eject button. The instrument will turn off.

Warnings
Keep the instrument, sensors and other components out of the reach and sight of children. Small parts may pose a choking hazard.
Handle the bottle and sensors with clean, dry hands.
Dispose of the used bottle and sensors according to local regulations.
Handling blood can be dangerous: use extreme caution when handling blood, sensors, lancets, and the meter.

Conservation
Store the sensor bottle in a dry place, at a temperature of 4-30°C. Do not freeze. Avoid heat and direct sunlight.
Store all unused sensors in the original bottle and close the cap tightly after removing one to preserve the quality of the sensor. Do not transfer sensors to other containers.
Do not use sensors beyond their expiration date.
Do not use the sensors more than 12 months after first opening their bottle. It is recommended to write the disposal date on the label (first opening date + 12 months).
The strips in closed packaging have a validity of 24 months from the date of manufacture.

Format
Pack of 50 sensors.

Code 49198