Accu-Chek Guide Blood Glucose Test Strips 25 Pieces Retail Pack Accu-Chek
56% off
€14,69
€33,33
Unit price
/
Unavailable
Tax included, shipping and discounts calculated at checkout.
ROCHE DIAGN D.CARE | SKU:
938807664
Accu-Chek Guide Blood Glucose Test Strips 25 Pieces Retail Pack Accu-Chek is backordered and will ship as soon as it is back in stock.
Shipping Costs and Times
Shipping Costs and Times
- Order fulfillment within 24 hours and delivery within the following 48/72 hours.
- Shipping cost: always free for orders over €49.90, otherwise it costs €4.99.
Payments
Payments
Payment information is processed securely. We do not store credit card information or have access to your credit card information.
Returns and Refunds
Returns and Refunds
You can return and receive a refund for the item within 30 days. See full policy here.

Do you need help?
Our customer service is here to help you!
- Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
- For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .
We are always at your side to offer you fast and effective support!
Description
Description
ACCU-CHEK GUIDE BLOOD GLUCOSE TEST STRIPS 25 PIECES RETAIL PACK ACCU-CHEK
ACCU-CHEK GUIDE
ACCU CHEK
Guide
25 Strips Retail
Description
Accu-Chek Guide is the blood glucose monitoring system indicated for people with diabetes for home self-monitoring and for in vitro diagnostic use by healthcare professionals in clinical settings.
The Accu-Chek Guide system is a unique solution designed to meet the diverse needs of people with diabetes and healthcare professionals. System features such as the patented, spill-proof oval bottle and new test strips with a large blood sample application area are a number of smart solutions that make blood glucose testing easier.
The system offers excellent accuracy and precision. Accu-Chek Guide test strips have been subjected to a wide variety of tests, including external site studies and extensive internal testing. The study results show that the test strips provide accurate and reliable measurements under a variety of conditions.
Accu-Chek Guide strips boast three main features:
- Anti-spill oval bottle: the innovative design of the strip container bottle prevents it from tipping and makes it easy to remove just one strip at a time. The oval shape makes it pocket-sized and the protruding cap is easy to open.
- Large blood sample application area: The new Accu-Chek Guide test strips allow you to apply a small blood sample anywhere on the wide tip, highlighted in yellow and intuitively indicated by red blood drops drawn near the area.
- Excellent accuracy (10/10): The Accu-Chek Guide system complies with ISO 15197:2013/EN ISO 15197:2015 and offers accuracy that exceeds the required requirements, ensuring reliable results.
Technical specifications :
System accuracy :
1. System accuracy results for glucose concentrations less than 100 mg/dL (less than 5.55 mmol/L):
- within ±5 mg/dl (within ±0.28 mmol/l): 175/186 (94.1%);
- within ±10 mg/dl (within ±0.56 mmol/l): 186/186 (100%);
- within ±15 mg/dl (within ±0.83 mmol/l): 186/186 (100%).
2. System accuracy results for glucose concentrations equal to or greater than 100 mg/dL (equal to or greater than 5.55 mmol/L):
- within ±5 mg/dl: 296/414 (71.5%);
- within ±10 mg/dl: 404/414 (97.6%);
- within ±15 mg/dl: 413/414 (99.8%);
3. System accuracy results for glucose concentrations between 14 mg/ml (0.78 mmol/l) and 578 mg/ml (32.1 mmol/l):
- within ±15 mg/dl or within ±15% (within ±0.83 mmol/l or within ±15%): 599/600 (99.8%).
Components
Composition of reagents:
Mediator 6.6%;
FAD-GDH enzyme 21.3%;
Swab 22.6%;
Stabilizer 0.3%;
Non-reactive component 49.2%;
How to use
Read the test strip package insert carefully.
Place the sample on the suction area of the strip, highlighted in yellow. Wait approximately 4 seconds, for the duration of the measurement cycle.
The yellow test zone on the strip provides visual confirmation that the sample has been applied correctly.
Warnings
Lipemic (triglyceride) samples >1800 mg/dL (>20.3 mmol/L) may produce elevated glucose results.
Do not use this system if you are undergoing intravenous infusion of ascorbic acid.
Do not use this system during xylose uptake testing.
Conservation
Store strips at a temperature between 4°C and 30°C.
Test strips can be used until the expiration date indicated on the package.
This applies to test strips from a new, unopened bottle as well as test strips from a previously opened bottle.
Format
Pack of 25 strips.
Cod. 08137358001
Accu-Chek Guide is the blood glucose monitoring system indicated for people with diabetes for home self-monitoring and for in vitro diagnostic use by healthcare professionals in clinical settings.
The Accu-Chek Guide system is a unique solution designed to meet the diverse needs of people with diabetes and healthcare professionals. System features such as the patented, spill-proof oval bottle and new test strips with a large blood sample application area are a number of smart solutions that make blood glucose testing easier.
The system offers excellent accuracy and precision. Accu-Chek Guide test strips have been subjected to a wide variety of tests, including external site studies and extensive internal testing. The study results show that the test strips provide accurate and reliable measurements under a variety of conditions.
Accu-Chek Guide strips boast three main features:
- Anti-spill oval bottle: the innovative design of the strip container bottle prevents it from tipping and makes it easy to remove just one strip at a time. The oval shape makes it pocket-sized and the protruding cap is easy to open.
- Large blood sample application area: The new Accu-Chek Guide test strips allow you to apply a small blood sample anywhere on the wide tip, highlighted in yellow and intuitively indicated by red blood drops drawn near the area.
- Excellent accuracy (10/10): The Accu-Chek Guide system complies with ISO 15197:2013/EN ISO 15197:2015 and offers accuracy that exceeds the required requirements, ensuring reliable results.
Technical specifications :
Capillary aspiration of the sample | Yes |
Reading time | <4 seconds |
Measuring range | 10-600 mg/dl |
Temperature range | 4-45°C |
Working humidity range | 10-90% |
Hematocrit range | 10-65% |
Use at altitude | Yes up to 3094 m above sea level |
Biological liquid used for the sample | Capillary, venous, neonatal and arterial blood |
Minimum sample quantity | 0.6 mcl |
Capillary absorption | Yes |
Sampling method | Automatic absorption for blood sample aspiration |
Principle of reading tests | Electrochemical - FAD-dependent glucose dehydrogenase (GDH) enzyme |
Blood glucose meter to use | Accu-Chek Guide |
System accuracy :
1. System accuracy results for glucose concentrations less than 100 mg/dL (less than 5.55 mmol/L):
- within ±5 mg/dl (within ±0.28 mmol/l): 175/186 (94.1%);
- within ±10 mg/dl (within ±0.56 mmol/l): 186/186 (100%);
- within ±15 mg/dl (within ±0.83 mmol/l): 186/186 (100%).
2. System accuracy results for glucose concentrations equal to or greater than 100 mg/dL (equal to or greater than 5.55 mmol/L):
- within ±5 mg/dl: 296/414 (71.5%);
- within ±10 mg/dl: 404/414 (97.6%);
- within ±15 mg/dl: 413/414 (99.8%);
3. System accuracy results for glucose concentrations between 14 mg/ml (0.78 mmol/l) and 578 mg/ml (32.1 mmol/l):
- within ±15 mg/dl or within ±15% (within ±0.83 mmol/l or within ±15%): 599/600 (99.8%).
Components
Composition of reagents:
Mediator 6.6%;
FAD-GDH enzyme 21.3%;
Swab 22.6%;
Stabilizer 0.3%;
Non-reactive component 49.2%;
How to use
Read the test strip package insert carefully.
Place the sample on the suction area of the strip, highlighted in yellow. Wait approximately 4 seconds, for the duration of the measurement cycle.
The yellow test zone on the strip provides visual confirmation that the sample has been applied correctly.
Warnings
Lipemic (triglyceride) samples >1800 mg/dL (>20.3 mmol/L) may produce elevated glucose results.
Do not use this system if you are undergoing intravenous infusion of ascorbic acid.
Do not use this system during xylose uptake testing.
Conservation
Store strips at a temperature between 4°C and 30°C.
Test strips can be used until the expiration date indicated on the package.
This applies to test strips from a new, unopened bottle as well as test strips from a previously opened bottle.
Format
Pack of 25 strips.
Cod. 08137358001