FREE SHIPPING ON ORDERS OVER €49.90

Pic Glucotest Glucometer Kit

€30,42 €45,00
Tax included, shipping and discounts calculated at checkout.
PIC  |  SKU: 927306617  |  Barcode: 8058090001140


Shipping Costs and Times

  • Order fulfilled in 24h
  • Italy, including islands, Free from €49.90
  • Orders under €49.90: €4.99
  • Europe starting from €11

Read the full policy

Payments

Payment information is processed securely. We do not store credit card information or have access to your credit card information.

Returns and Refunds

You can return and receive a refund for the item within 30 days. See full policy here.

5.0 kg
Assistenza Clienti BFarma +39 347 093 4913

Do you need help?

Our customer service is here to help you!

  • Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
  • For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .

We are always at your side to offer you fast and effective support!

Description

PIC GLUCOTEST GLUCOMETER KIT PIC



Pic Glucotest

Description
Complete kit for blood glucose measurement.
The glucose contained in the blood sample reacts with the reagent on the test strip, creating a small electrical current. The amount of current generated depends on the amount of glucose present in the blood.
The Pic GlucoTest glucometer measures the created current and converts the measurement into the blood glucose concentration. The blood glucose result is displayed on the glucometer's LCD display.
The gold electrode on the strip ensures high accuracy and precision.

Technical specifications
Blood glucose measurement Specificity for beta-D-glucose
Method and operating principle Electrochemical, potentiometric
Enzymatic composition of 100 test strips Glucose Oxidase (GOD)
Potassium Ferricyanide (mediator)
Test strips Exclusively Pic Gluco Test
Correlation Plasma equivalent
Sample Fresh capillary whole blood
Measurement range 10-600 mg/dL (0.6-33.3 mmol/L)
Response time 5 seconds
Sample volume 0.3 mcL
Hematocrit range that does not alter the measurement 20-60%
Calibration None
Sampling Aspiration of blood sample by capillarity
Alternative site testing (AST) Allowed
Memory capacity Last 500 results with date and time
Connection Data transfer capability to PC via USB
Output specifications Connecting cable can be requested
Battery life Approximately 1,000 tests, battery life may vary depending on measurement conditions
Operating environment Between 10 °C and 45 °C (50-113 °F)
Dimensions 50x93x18 mm
Weight 50 g (with battery)
Automatic shutdown 1 minute after starting from the ON button
3 minutes after starting with the insertion of the test strip

How to use
To obtain accurate results, allow the glucometer to acclimatize to the surrounding environment (temperature between 10 °C and 45 °C).
If the ambient temperature is above or below the correct range, a thermometer icon will appear on the display. Move to an area where the temperature is between 10 °C and 45 °C, wait 30 minutes, and perform a test. Do not artificially heat or cool the glucometer.

Remove a new test strip from the container and reseal it tightly.
The glucometer turns on using one of the following two methods: pressing the ON/OFF button and/or inserting the test strip into the slot while off.
When the blood drop symbol flashes (Blood Stand-by screen), the glucometer is ready to perform the test.
Bring your finger close to the end of the strip until the golden window of the strip is completely filled with blood. The blood will be automatically drawn into the strip.
If the beeper is active, the glucometer will emit a signal to indicate that the measurement is starting. After applying blood to the strip, a countdown from 5 to 1 seconds will appear on the display. After 5 seconds, the result will be displayed. The blood glucose result is displayed in mg/dL or mmol/L.

For accurate results, no more than 20 seconds should pass between sample collection and measurement (sample evaporation can cause a test result higher than the actual value). The blood sample volume must be at least 0.3 mcL.
The glucometer stores measurement results with the date of execution in its memory.

If the test result is below 70 mg/dL or "LO" appears, it may indicate possible hypoglycemia. This condition may require immediate intervention based on your doctor's recommendations. Although this result may be due to an unlikely analysis error, it is preferable to intervene immediately and then repeat the test.
If the test result is above 180 mg/dL and "HI" appears, it may indicate hyperglycemia. If there are no symptoms, repeat the test. If results still exceed 180 mg/dL and symptoms are present, consult your doctor for guidance on what action to take.

Cleaning the glucometer:
Avoid dust. If you need to clean the glucometer, carefully follow the following guidelines.
To prevent glucometer malfunction, avoid the penetration of blood, moisture, dirt, or dust into the strip slot.
To clean the glucometer, use a lint-free cloth dampened with water. Wring the cloth thoroughly before use. Do not use an abrasive cloth or an antiseptic solution as they may damage the display.

Storage
Store the glucometer, test strips, control solution, control strip, lancing device, lancets, and manuals inside the appropriate case.
Store test strips at an ambient temperature between 2 °C and 32 °C. Do not refrigerate or freeze.
Frozen and thawed reagents can produce inaccurate blood glucose results.
Protect the test strip slot from dust.
Do not expose test strips to moisture and direct sunlight, and store them in a cool, dry place. Close the container tightly after removing a test strip. The test strip container is able to maintain the correct humidity, so do not transfer the test strips to any other container.
Store Pic Control Solution at a temperature between 8 °C and 30 °C.

Format
The kit contains:
- 1 Pic GlucoTest glucometer;
- 1 Digitest lancing device;
- 5 G32 lancing lancets and 5 G30 lancing lancets;
- 1 control strip;
- 10 Pic GlucoTest test strips;
- 1 3V CR2032 button battery;
- 1 kit user manual;
- 1 quick guide;
- 1 self-monitoring diary;
- 1 strip manual;
- 1 instrument carrying case.

Code. 0205400010000

Product Details

  • Legislative class
    In vitro Diagnostic Medical Device Directive 98/79/EEC
  • Deductible Product
    Yes