Free shipping from €49.90

10% Extra Discount until February 28th! Use the code: Hellobfarma

MUNUS MEDICAL SELF-DIAGNOSTIC TEST OCCULT BLOOD MUNUS

€9,90
Tax included, shipping and discounts calculated at checkout.
MUNUS INTERNATIONAL  |  SKU: 986885162  |  Barcode: 6936983121118



Shipping Costs and Times

  • Order fulfillment within 24 hours and delivery within the following 48/72 hours.
  • Shipping cost: always free for orders over €49.90, otherwise it costs €4.99.

Payments

Payment information is processed securely. We do not store credit card information or have access to your credit card information.

Returns and Refunds

You can return and receive a refund for the item within 30 days. See full policy here.

Assistenza Clienti BFarma +39 347 093 4913

Do you need help?

Our customer service is here to help you!

  • Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
  • For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .

We are always at your side to offer you fast and effective support!

Description

MUNUS MEDICAL SELF-DIAGNOSTIC TEST OCCULT BLOOD MUNUS



MUNUS MEDICAL

OCCULT BLOOD TEST

Description
Rapid chromatographic immunoassay for the qualitative detection of human occult blood in feces.
The membrane is pre-coated with an anti-hemoglobin antibody in the test line region. During analysis, the sample reacts with the anti-hemoglobin antibody-coated particles.
The mixture migrates chromatographically upward by capillary action on the membrane, reacting with the anti-hemoglobin antibody present on the membrane, forming a colored line. The presence of this colored line in the test line region indicates a positive result, while its absence indicates a negative result.
As a procedural control, a colored line always appears in the control region to indicate that the correct volume of sample has been added and that capillary action has acted on the membrane.

How to use
Before testing, allow the sample and swab to reach room temperature (15-30°C).
Do not collect samples during menstruation or within three days of it or if patients have bleeding hemorrhoids or blood in their urine.
Excessive alcohol, aspirin, and other medications can cause gastrointestinal irritation that can lead to occult bleeding. Discontinue these substances at least 48 hours before the test.
No dietary restrictions are required before using the Occult Blood Test.
The stool sample should be placed in the appropriate collector. Use the stool collector to avoid contamination of the sample with any type of chemical so that the sample is not adulterated.
Unscrew the cap of the sample collection tube and then randomly insert the sample collection applicator into at least 3 different locations on the stool sample. Do not dig into the stool sample. Screw and tighten the cap onto the sample collection tube and shake vigorously to mix the sample and extraction buffer.
Allow the pouch to reach room temperature before opening. Remove the test cassette from the pouch and use it as soon as possible. For best results, perform the test immediately after opening the pouch.
Hold the sample collection tube upright and open the cap. Invert the sample collection tube and transfer 2 drops of the extracted sample (approximately 80 mcL) into the sample well (S) of the test cassette, then start the timer. Avoid trapping air bubbles in the sample well (S).
Read the result after 5 minutes. Do not read the results after 10 minutes.
Interpretation of results
POSITIVE: Two colored lines appear. One colored line should be in the control line region (C) and another colored line should be in the test line region (T).
The intensity of the color in the test line region (T) will vary depending on the concentration of fecal occult blood present in the specimen. Therefore, any shade of color in the test line region (T) should be considered positive.

NEGATIVE: A colored line appears in the control line region (C). No line appears in the test line region (T).

NULL: Control line does not appear. Insufficient sample volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test. If the problem persists, discontinue use of the test kit immediately and contact your local distributor.

Warnings
For in vitro diagnostic self-testing only.
Do not use after expiration date.
The test must remain in the sealed pouch until use.
Do not eat, drink, or smoke in the area where specimens or kits are handled.
Handle all specimens as if they contain infectious agents. Observe accepted precautions against microbiological hazards during all procedures and dispose of specimens according to standard procedures.
Used tests must be disposed of in accordance with local regulations.
Humidity and temperature can negatively affect results.
Keep out of reach of children.
The test will only indicate the presence of occult blood in the stool, the presence of blood in the stool does not necessarily indicate colorectal bleeding.
As with all diagnostic tests, it is essential to consider all results in conjunction with other clinical information available to the physician.
If doubtful results are obtained, further clinically available tests are necessary.

Conservation
The kit can be stored at room temperature or refrigerated (2-30 °C). Do not freeze.
The test cassette is stable until the expiration date printed on the sealed pouch. The test cassette must remain in the sealed pouch until use. Do not use beyond the expiration date.
Validity with intact packaging: 24 months.

Format
The kit contains:
- dipstick test;
- stool collector;
- reaction tube;
- sample collection tube with extraction swab;
- package leaflet.

Bibliography
1. Simon JB. Occult Blood Screening for Colorectal Carcinoma: A Critical Review, Gastroenterology, Vol. 1985; 88:820.
2. Blebea J, Mcpherson RA. False-Positive Guaiac Testing With Iodine, Arch Pathol Lab Med, 1985;109:437-40.

Cod. MM-TFO-602H