PULSE OXIMETER SCREEN CHECK TEST SCREEN ITALIA
Sold out
€49,00
Unit price
/
Unavailable
Tax included, shipping and discounts calculated at checkout.
SCREEN ITALIA | SKU:
970791772
Notify me when it's back in stock!
Write us your email, you will be notified when this product becomes available again!
PULSE OXIMETER SCREEN CHECK TEST SCREEN ITALIA is backordered and will ship as soon as it is back in stock.
Shipping Costs and Times
Shipping Costs and Times
- Order fulfillment within 24 hours and delivery within the following 48/72 hours.
- Shipping cost: always free for orders over €49.90, otherwise it costs €4.99.
Payments
Payments
Payment information is processed securely. We do not store credit card information or have access to your credit card information.
Returns and Refunds
Returns and Refunds
You can return and receive a refund for the item within 30 days. See full policy here.

Do you need help?
Our customer service is here to help you!
- Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
- For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .
We are always at your side to offer you fast and effective support!
Description
Description
PULSE OXIMETER SCREEN CHECK TEST SCREEN ITALIA
SCREEN CHECK TEST
Pulse Oximeter
Description
In vitro diagnostic medical device CE 0482.
Measures blood oxygen saturation and human body pulse from finger. Detects non-invasively the real content of oxyhemoglobin (HbO2) in arterial blood. It can also be used for pre or post sports activity measurements (never during).
Read the warnings and instructions for use carefully.
Usable in a wide range of fields: family, hospital, anesthesiology operating rooms, pediatric and intensive care units, oxygen bars, social-health care and sports medicine institutions. Also available in Pharmacies.
How to use
Press and release the button to turn on the device; press and hold the button for about one second. The oximeter displays a parameter setting interface. Press or hold the button to perform corresponding operations. Press and hold to set an item or press to change an option or change the display mode. Press means no more than 0.5 seconds, while hold means more than 0.5 seconds.
Insert one finger fully into the measuring parts of the oximeter, hold the nail surface upward and release the clip, then press the power button to turn on the oximeter.
If you have not yet fully inserted your finger into the cavity, the measurement result may be inaccurate.
Do not vibrate your finger during measurement, make sure your body does not move. After the values stabilize, read the measured values of oxygen saturation and pulse rate on the screen.
NOTE: The oximeter will automatically turn off 10 seconds after your finger is removed.
Warnings
Do not attempt to service the oximeter unless you are a professional technician.
Only professionals with maintenance qualifications can perform the necessary internal maintenance.
Periodically change the contact position between the oximeter probe and the finger for a measurement. Adjust the probe position before measurement and check the skin integrity, the blood circulation condition of the finger and the position of the finger.
This product is not applicable to the examination of newborns.
If the measured value exceeds the normal range, consult a doctor promptly, even if you are sure that the instrument is not malfunctioning.
Do not directly expose your eyes to the light-emitting components of the oximeter, as this may cause eye damage.
Do not expose the device to lint, dust, light (including sunlight), pets, vermin, or children, etc.
Use by adults or children weighing less than 30 kg is prohibited.
Between uses it takes more than half an hour to warm up or cool down from the minimum/maximum storage temperature until it is ready for its intended use.
The patient is an expected operator.
The lay operator or responsible lay organization should contact the manufacturer or the manufacturer's representative for the following matters:
• assistance in setting up, using, or maintaining the equipment or system, if necessary;
• to report unexpected operations or events.
The following factors may disturb or influence the accuracy of the test:
- this product is used in an environment where there are high-frequency devices, such as high-frequency electric knives and CT scanners;
- the user suffers from hypotension, severe vascular atrophy, severe anemia or oxygen deficiency;
- the user is in sudden cardiac arrest or shock;
- A finger with nail polish or a fake nail can cause incorrect readings of the oxygen saturation of the wrist.
Be aware of the effects of degraded sensors which can impair performance or cause other problems.
Do not self-diagnose or treat based on the measurement results, but consult a doctor.
Note: the product has no contraindications.
The device has no side effects if administered correctly and the residual risk is acceptable.
-Do not use the oximeter in environments with flammable gases, flammable anesthetics or other flammable substances.
- Do not attempt to charge a common dry cell battery, as this may cause leakage, fire or even explosion. Dispose of used batteries in accordance with environmental protection regulations.
- Do not use the oximeter in MRI or CT environments.
- Do not use the oximeter when it is wet with water or overflow. steam condensation. Avoid moving the oximeter from an excessively cold environment to a high temperature humid environment.
- For safety reasons, no modification of this equipment is permitted.
- Do not use accessories and detachable parts not specified or authorized by the manufacturer. Otherwise, damage to the unit or danger to the user or patients may occur.
Conservation
Wrapped products should be stored in well-ventilated rooms without corrosive gases and at an ambient temperature of -10°C-50°C, relative humidity less than 93% (non-condensing) and atmospheric pressure of 50–106 kPa.
Format
Box containing 1 piece.
Code JPD-500F
In vitro diagnostic medical device CE 0482.
Measures blood oxygen saturation and human body pulse from finger. Detects non-invasively the real content of oxyhemoglobin (HbO2) in arterial blood. It can also be used for pre or post sports activity measurements (never during).
Read the warnings and instructions for use carefully.
Usable in a wide range of fields: family, hospital, anesthesiology operating rooms, pediatric and intensive care units, oxygen bars, social-health care and sports medicine institutions. Also available in Pharmacies.
How to use
Press and release the button to turn on the device; press and hold the button for about one second. The oximeter displays a parameter setting interface. Press or hold the button to perform corresponding operations. Press and hold to set an item or press to change an option or change the display mode. Press means no more than 0.5 seconds, while hold means more than 0.5 seconds.
Insert one finger fully into the measuring parts of the oximeter, hold the nail surface upward and release the clip, then press the power button to turn on the oximeter.
If you have not yet fully inserted your finger into the cavity, the measurement result may be inaccurate.
Do not vibrate your finger during measurement, make sure your body does not move. After the values stabilize, read the measured values of oxygen saturation and pulse rate on the screen.
NOTE: The oximeter will automatically turn off 10 seconds after your finger is removed.
Warnings
Do not attempt to service the oximeter unless you are a professional technician.
Only professionals with maintenance qualifications can perform the necessary internal maintenance.
Periodically change the contact position between the oximeter probe and the finger for a measurement. Adjust the probe position before measurement and check the skin integrity, the blood circulation condition of the finger and the position of the finger.
This product is not applicable to the examination of newborns.
If the measured value exceeds the normal range, consult a doctor promptly, even if you are sure that the instrument is not malfunctioning.
Do not directly expose your eyes to the light-emitting components of the oximeter, as this may cause eye damage.
Do not expose the device to lint, dust, light (including sunlight), pets, vermin, or children, etc.
Use by adults or children weighing less than 30 kg is prohibited.
Between uses it takes more than half an hour to warm up or cool down from the minimum/maximum storage temperature until it is ready for its intended use.
The patient is an expected operator.
The lay operator or responsible lay organization should contact the manufacturer or the manufacturer's representative for the following matters:
• assistance in setting up, using, or maintaining the equipment or system, if necessary;
• to report unexpected operations or events.
The following factors may disturb or influence the accuracy of the test:
- this product is used in an environment where there are high-frequency devices, such as high-frequency electric knives and CT scanners;
- the user suffers from hypotension, severe vascular atrophy, severe anemia or oxygen deficiency;
- the user is in sudden cardiac arrest or shock;
- A finger with nail polish or a fake nail can cause incorrect readings of the oxygen saturation of the wrist.
Be aware of the effects of degraded sensors which can impair performance or cause other problems.
Do not self-diagnose or treat based on the measurement results, but consult a doctor.
Note: the product has no contraindications.
The device has no side effects if administered correctly and the residual risk is acceptable.
-Do not use the oximeter in environments with flammable gases, flammable anesthetics or other flammable substances.
- Do not attempt to charge a common dry cell battery, as this may cause leakage, fire or even explosion. Dispose of used batteries in accordance with environmental protection regulations.
- Do not use the oximeter in MRI or CT environments.
- Do not use the oximeter when it is wet with water or overflow. steam condensation. Avoid moving the oximeter from an excessively cold environment to a high temperature humid environment.
- For safety reasons, no modification of this equipment is permitted.
- Do not use accessories and detachable parts not specified or authorized by the manufacturer. Otherwise, damage to the unit or danger to the user or patients may occur.
Conservation
Wrapped products should be stored in well-ventilated rooms without corrosive gases and at an ambient temperature of -10°C-50°C, relative humidity less than 93% (non-condensing) and atmospheric pressure of 50–106 kPa.
Format
Box containing 1 piece.
Code JPD-500F