Free shipping from €49.90

10% Extra Discount until February 28th! Use the code: Hellobfarma

Self-Test Vitamin D 1 Piece Sofarmapiu' Sofarmapiu'

€6,28 €9,90
Tax included, shipping and discounts calculated at checkout.
SOFARMAPIU  |  SKU: 986885390  |  Barcode: 8054320670209


Shipping Costs and Times

  • Order fulfillment within 24 hours and delivery within the following 48/72 hours.
  • Shipping cost: always free for orders over €49.90, otherwise it costs €4.99.

Payments

Payment information is processed securely. We do not store credit card information or have access to your credit card information.

Returns and Refunds

You can return and receive a refund for the item within 30 days. See full policy here.

Assistenza Clienti BFarma +39 347 093 4913

Do you need help?

Our customer service is here to help you!

  • Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
  • For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .

We are always at your side to offer you fast and effective support!

Description

SELF-DIAGNOSTIC TEST VITAMIN D 1 PIECE SOFARMAPIU' SOFARMAPIU'



SoFarma

VITAMIN D TEST

Description
Rapid immunochromatographic test for the semi-quantitative detection of 25-hydroxyvitamin-D in human blood from fingerstick.
This test can provide a preliminary diagnostic result and can be used in screening for vitamin D deficiencies.
Immunoassay based on the principle of competitive binding. During the test, the mixture migrates upward on the membrane chromatographically by capillary action. The membrane is pre-coated with 25(OH)D antigens on the test line (T) region of the test strip. During the test, the 25(OH)D present in the sample will compete with the 25(OH)D present on the test line (T) due to the limited amount of anti-25 OH vitamin D antibodies present in the conjugate. The higher the concentration of 25(OH)D in the sample, the fainter the T line will be.
The result can be interpreted according to the color chart provided with this kit.
With the procedural control function, a colored line will always appear in the control line area (C) to indicate that sufficient sample volume has been added and the membrane has been saturated.

How to use
Wash hands with soap and rinse with clean warm water.
Allow the package to reach room temperature before opening. Open the package, remove the test and place it on a clean, flat surface. Test within one hour of opening, best results will be obtained by testing immediately after opening the foil package.
Remove the dropper, swab vial, sterile lancet, and alcohol wipe, placing them near the test.
Gently pull to remove the protective cap from the lancet. Use the alcohol wipe to clean the pad of your middle or ring finger, where you will prick your finger. Wait until the area is dry again. Press the lancet, from the side where the cap was removed; the tip automatically and safely retracts after use.
Massage your hand toward the tip of the middle or ring finger that was pricked (without touching the puncture site) to obtain a drop of blood.
Touch the capillary dropper to the blood, without squeezing the bulb. The blood will migrate into the capillary dropper until it reaches the line indicated on the dropper. You can massage your finger again to obtain more blood if the fill line has not been reached. Try to avoid the formation of air bubbles as much as possible.
Pour the collected blood into the sample well (S) on the device by pressing the dropper bulb.
Wait until the blood has completely poured into the well. Unscrew the cap of the swab vial and add 2 drops of swab to the swab well (B) on the device and start the timer.
Wait for the colored line(s) to appear. Read the results after 10 minutes. Compare the intensity of the T-line with the “Vitamin D Color Card” provided in the kit to interpret the level of vitamin D in your blood. Do not interpret the result after 20 minutes.

Reading the results
25-OH Vitamin D Level Reference range (ng/mL) Reference range (mcmol/L)
Lacking 0-10 0-25
Insufficient 10-30 25-75
Sufficient 30-100 75-250

- Deficient: Two colored lines appear. One line in the control region (C) while another line should appear in the test region (T). The line in the test region (T) is darker than or equal to the 10 mcg/mL line shown on the DEFICIENT color card provided in the kit.
- Poor: Two colored lines appear. One line in the control region (C) while another line should appear in the test region (T). The line in the test region (T) is darker than the 30 mcg/mL line and lighter than the 10 mcg/mL line, both of which are shown on the color card provided with the kit.
- Sufficient: Two colored lines appear, one line should always appear in the control region (C) while another line should appear in the test region (T). The intensity of the line in the test region (T) is lighter than or equal to the 30 mcg/mL line shown on the color card.
- Excessive: A colored line appears in the control region (C). No colored line appears in the test region (T). If the result is excess Vitamin D, it is recommended to consult your doctor.
- Invalid: The control line does not appear. The most likely reasons for the control line not appearing are insufficient specimen volume or incorrect procedural techniques. Review the procedure and repeat the test with a new kit. If the problem persists, discontinue use of the kit immediately and contact your local distributor.

Warnings
Please read all the information in this leaflet before performing the test.
For in vitro self-diagnostic use only.
Do not eat, drink or smoke in the specimen or kit handling area.
Please do not use the test if the sealed package is damaged or opened.
The kit is intended to be used as a preliminary test and repeated abnormal results should be discussed with a doctor or specialist.
Strictly follow the indicated timings.
Use the test only once. Do not disassemble or touch the test window on the stand.
The kit must not be frozen or used beyond the expiration date printed on the package.
Keep out of reach of children.
Once used, the test must be disposed of according to local regulations.
The Vitamin D Rapid Test provides only a semi-quantitative analytical result. A secondary analytical method must be used to confirm the result.
It is possible that technical or procedural errors, as well as interference from substances in the blood sample, may cause erroneous results. As with all diagnostic tests, all results must be evaluated together with other clinical data available to your doctor. In the case of a questionable result, clinical testing with additional testing methods is necessary.

Conservation
Store packaged at room temperature or refrigerated (2-30°C).
Do not freeze.
The test is stable until the expiration date printed on the sealed pouch or unopened box. The test must remain in the sealed pouch until use. Do not use beyond the expiration date.
Validity with intact packaging: 24 months.

Format
The package contains:
- test;
- dropper;
- swab;
- alcohol wipe;
- hands;
- package leaflet;
- color card.

Cod. SF006