Sofarmapiu' Multidrug Rapid Self-Test Sofarmapiu'
33% off
€11,66
€17,50
Unit price
/
Unavailable
Tax included, shipping and discounts calculated at checkout.
SOFARMAPIU | SKU:
986872289
Sofarmapiu' Multidrug Rapid Self-Test Sofarmapiu' is backordered and will ship as soon as it is back in stock.
undefined
Shipping Costs and Times
Shipping Costs and Times
- Order fulfillment within 24 hours and delivery within the following 48/72 hours.
- Shipping cost: always free for orders over €49.90, otherwise it costs €4.99.
Payments
Payments
Payment information is processed securely. We do not store credit card information or have access to your credit card information.
Returns and Refunds
Returns and Refunds
You can return and receive a refund for the item within 30 days. See full policy here.

Do you need help?
Our customer service is here to help you!
- Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
- For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .
We are always at your side to offer you fast and effective support!
Description
Description
SOFARMAPIU' MULTI-DRUG RAPID SELF-DIAGNOSTIC TEST SOFARMAPIU'
SoFarma
MULTI-DRUG TESTS
Description
Lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and metabolites in urine.
How to use
Collect the urine sample in a clean, dry container. Urine samples collected at any time of the day can be used.
Urine samples can be stored at 2-8°C for up to 48 hours before testing.
Before performing the test, bring the test device and urine sample to room temperature (15-30°C).
Remove the test device and use it as soon as possible. Remove the outer cap of the test, with the arrows pointing towards the urine sample, immerse the device vertically in the urine sample for at least 10-15 seconds up to the wavy lines of the strips, taking care not to go beyond the arrows on the panel.
Place the test device on a clean, flat, non-absorbent surface.
Turn on the timer and wait for the lines to color. Read the result after 5 minutes, do not interpret the result after 10 minutes.
Interpretation of results
NEGATIVE: Two colored lines appear, the test line (T) and the control line (C). The color intensity of the test line (T) may vary but this has no relevance for the interpretation of the test results, the result must still be considered negative.
A negative result indicates that the drug concentration in the urine specimen is below the cut-off level or limit of detection for that specific drug.
POSITIVE: Only the control line (C) appears. The test line (T) does not appear.
A positive result indicates that the drug concentration exceeds the cut-off or limit of detection for that specific drug.
INVALID: No line appears or only the test line (T) appears. The result is considered invalid. It is recommended to repeat the test. If the problem persists, contact the seller.
Warnings
Product not intended for medical or diagnostic use.
Keep the device in the closed package until ready to use.
All samples should be considered potentially hazardous and should therefore be handled with the precautions for use with potentially infectious products.
After use, the test must be disposed of according to local regulations.
The test provides a qualitative result that should be considered preliminary. A second analytical method should be considered to confirm the result. Gas chromatography-mass spectrometry (GC/MS) are considered preferred confirmatory methods.
It is possible that technical or procedural errors, as well as interfering substances present in the urine sample, may cause erroneous results.
A positive result indicates the presence of the drug or its metabolites but not the level of intoxication, route of administration, or concentration in urine.
A negative result does not necessarily mean that the urine sample is drug-free. A negative result may occur when the drug is present but at a concentration below the detection level of the test.
The test cannot distinguish between the drug and a medicine containing the same substance.
Conservation
Store at a temperature between 2°C and 30°C. Do not freeze.
Validity with intact packaging: 24 months.
Format
The kit contains:
- testing device;
- dropper;
- package leaflet.
Cod. SF012
Lateral flow chromatographic immunoassay for the qualitative detection of multiple drugs and metabolites in urine.
How to use
Collect the urine sample in a clean, dry container. Urine samples collected at any time of the day can be used.
Urine samples can be stored at 2-8°C for up to 48 hours before testing.
Before performing the test, bring the test device and urine sample to room temperature (15-30°C).
Remove the test device and use it as soon as possible. Remove the outer cap of the test, with the arrows pointing towards the urine sample, immerse the device vertically in the urine sample for at least 10-15 seconds up to the wavy lines of the strips, taking care not to go beyond the arrows on the panel.
Place the test device on a clean, flat, non-absorbent surface.
Turn on the timer and wait for the lines to color. Read the result after 5 minutes, do not interpret the result after 10 minutes.
Interpretation of results
NEGATIVE: Two colored lines appear, the test line (T) and the control line (C). The color intensity of the test line (T) may vary but this has no relevance for the interpretation of the test results, the result must still be considered negative.
A negative result indicates that the drug concentration in the urine specimen is below the cut-off level or limit of detection for that specific drug.
POSITIVE: Only the control line (C) appears. The test line (T) does not appear.
A positive result indicates that the drug concentration exceeds the cut-off or limit of detection for that specific drug.
INVALID: No line appears or only the test line (T) appears. The result is considered invalid. It is recommended to repeat the test. If the problem persists, contact the seller.
Warnings
Product not intended for medical or diagnostic use.
Keep the device in the closed package until ready to use.
All samples should be considered potentially hazardous and should therefore be handled with the precautions for use with potentially infectious products.
After use, the test must be disposed of according to local regulations.
The test provides a qualitative result that should be considered preliminary. A second analytical method should be considered to confirm the result. Gas chromatography-mass spectrometry (GC/MS) are considered preferred confirmatory methods.
It is possible that technical or procedural errors, as well as interfering substances present in the urine sample, may cause erroneous results.
A positive result indicates the presence of the drug or its metabolites but not the level of intoxication, route of administration, or concentration in urine.
A negative result does not necessarily mean that the urine sample is drug-free. A negative result may occur when the drug is present but at a concentration below the detection level of the test.
The test cannot distinguish between the drug and a medicine containing the same substance.
Conservation
Store at a temperature between 2°C and 30°C. Do not freeze.
Validity with intact packaging: 24 months.
Format
The kit contains:
- testing device;
- dropper;
- package leaflet.
Cod. SF012