INFRARED FOREHEAD THERMOMETER DET-3012 DIACARE
Sold out
€49,90
Unit price
/
Unavailable
Tax included, shipping and discounts calculated at checkout.
DIACARE | SKU:
983780038
Notify me when it's back in stock!
Write us your email, you will be notified when this product becomes available again!
INFRARED FOREHEAD THERMOMETER DET-3012 DIACARE is backordered and will ship as soon as it is back in stock.
Shipping Costs and Times
Shipping Costs and Times
- Order fulfillment within 24 hours and delivery within the following 48/72 hours.
- Shipping cost: always free for orders over €49.90, otherwise it costs €4.99.
Payments
Payments
Payment information is processed securely. We do not store credit card information or have access to your credit card information.
Returns and Refunds
Returns and Refunds
You can return and receive a refund for the item within 30 days. See full policy here.

Do you need help?
Our customer service is here to help you!
- Contact us by phone, email or WhatsApp, from Monday to Friday, from 9:00 to 20:00 .
- For common questions, such as tracking your order or checking its fulfillment status, you can count on our artificial intelligence , available 24/7 .
We are always at your side to offer you fast and effective support!
Description
Description
INFRARED FOREHEAD THERMOMETER DET-3012 DIACARE
DIACARE
SEJOY
Forehead thermometer
DescriptionThermometer specifically designed for safe use on the forehead. The infrared forehead thermometer is a device that can measure the body temperature of people by detecting the intensity of infrared light emitted from the forehead. It converts the measured heat into a temperature reading displayed on the LCD. The infrared forehead thermometer is intended for intermittent measurement of human body temperature of the skin surface of the forehead by people of all ages. If used correctly, it will quickly assess the temperature accurately.
Infrared forehead thermometer measures the internal body temperature, which is the temperature of the vital organs of a body. This thermometer is designed to measure the temperature of the skin surface over the temporal artery, a major artery in the head. The temporal artery is connected to the heart via the carotid artery, which leads directly from the aorta, the main trunk of the arterial system. It provides a constant blood flow. Therefore, changes in body temperature are reflected in the forehead earlier than in other parts of the body such as the mouth, rectum, and armpits.
How to use
To ensure that your reading always accurately reflects your body temperature, the following factors should be considered.
1. It is important to know the normal temperature of each individual when they are well. This is the only way to accurately diagnose fever. To determine the normal temperature, take several readings when you are healthy. Re-measure with a standard digital thermometer to confirm.
2. Users must be indoors for 30 minutes before taking a measurement. Note: Users and the thermometer must be in the same room temperature for at least 10 minutes before taking a reading.
3. Users should not drink, eat or be physically active, bathe, shower, shampoo and dry hair before/during measurement. Remove hat and hair and wait 10 minutes before taking a reading.
4. Oils or cosmetics on the forehead may give a lower temperature reading than the actual one. Remove any dirt from the forehead before taking a reading. Wait at least 10 minutes after washing the forehead area before taking a reading.
5. Holding your hand on your forehead for any length of time will affect the temperature reading.
6. Do not take temperature over scar tissue, open sores, or abrasions.
7. Do not use the thermometer on a sweaty or perspiring forehead, as this may affect the reading.
8. Do not take a measurement during or immediately after breastfeeding a baby.
9. Do not take temperatures with this thermometer near very hot places, such as fireplaces and stoves.
10. The thermometer probe window is the most delicate part of the device. Do not touch the probe window. The accuracy of the reading may be affected if the probe window is damaged or dirty.
11. If the thermometer is stored in an environment significantly different from the testing location, place it in the testing location for approximately 30 minutes before use.
12. It is not intended for use in oxygen-rich environments and in the presence of flammable anesthetic mixture with air, oxygen or nitrous oxide.
To measure forehead temperature:
1. Press the Test button, the display is activated to show all segments. After self-check, Figure 2 appears on the display screen with voice, so you can start a new measurement.
2. Point the thermometer at the center of your forehead less than 5 cm away (see figure 3) and then press the test button. Note: Do not remove the thermometer from your forehead before you hear the voice.
3. Read the temperature on the display.
4. Press and hold the Test button to turn off.
Warnings
1. There is no gender or age limit for using the infrared forehead thermometer.
2. Do not touch the temperature probe with your hands.
3. The use of this forehead thermometer is not intended as a substitute for consultation with your doctor.
4. Do not allow children to take their temperatures unsupervised, some parts are small enough to be swallowed.
5. Never immerse this device in water or other liquids.
6. Do not modify this equipment without the manufacturer's authorization.
7. Do not expose the thermometer to extreme temperatures (below -25°C/-13°F or above 55°C/131°F) or excessive humidity (>95% RH).
8. Keep the battery away from children.
9. Remove the battery from the device when it is not in use for a long time.
10. Do not place the thermometer in direct sunlight or in contact with cotton wool, otherwise the accuracy will be affected.
11. Portable and mobile RF communications may affect the device. The device requires special precautions regarding EMC according to the EMC information provided in the accompanying documents.
12. ME equipment does not need to be cleaned and disinfected while in use.
Conservation
Store the thermometer in a dry, dust-free and contamination-free place away from direct sunlight.
Format
Package containing 1 thermometer.
Code DET-3012